Drager Evita 4 Ventilator
Condition: Pre-owned, Calibrated, Patient Ready
TECHNICAL SPECIFICATIONS
Ventilation Settings
- Ventilation Mode:
- IPPV, IPPVAssist (CMV, CMVAssist)
- SIMV, SIMVASB (SIMV, SIMV/Psupp)
- MMV, MMVASB (MMV, MMV/Psupp)
- BIPAP1), BIPAP1)ASB, BIPAP1)Assist (PCV+, PCV+/Psupp, PCV+Assist)
- APRV
- CPAP, CPAPASB (CPAP, CPAP/Psupp)
- ILV
- PPS (optional) - Enhancements:
- AutoFlowTM – Automatic adaptation of inspiratory flow in volume controlled modes
- ATCTM – Automatic Tube Compensation (optional)
- NIV – Mask Ventilation (optional) - Ventilation frequency (f): 0 to 100 /min, 0 to 150 /min (Neonatal)
- Inspiration time (Tinsp: 0.1 to 10 s
- Tidal volume (VT) (BTPS):
- 0.1 to 2.0 L (Adult)
- 0.02 to 0.3 L (Pediatric)
- 0.003 to 0.1 L (Neonatal) - Inspiratory flow
- 6 to 120 L/min (Adult)
- 6 to 30 L/min (Pediatric and Neonatal) - Inspiratory pressure: 0 to 80 mbar (cmH2O)
- PEEP / intermittent PEEP: 0 to 35 mbar (cmH2O)
- Pressureassist (PASB) (Psupp): 0 to 80 mbar (cmH2O)
- Rise time for inspiratory pressure: 0 to 2 s
- O2 concentration: 21 to 100 Vol.%
- Trigger sensitivity: 0.3 to 15 L/min
Measured values displayed
- Airway pressure: Peak pressure, plateau pressure, mean pressure, PEEP, min. pressure (0 to 99 mbar/cmH2O)
- Minute volume (MV), (BTPS): MV, MVspont, MVleak (0 to 99 L/min)
- Tidal volume (VT), (BTPS): Inspired VT, expired VT, VTPS (0 to 3999 mL)
- Breathing frequency (f): ftotal, fspon, fmand. (0 to150/bpm)
- O2 concentration (FiO2): Inspired O2 concentration (15 to 100 Vol.%)
- Lung mechanics
- Resistance ((0.0 to 600 mbar/L/s) (cmH2O/L/s)
- Compliance ((0.0 to 300 mL/mbar) (mL/cmH2O) - Breathing gas temperature: 18° to 51°C
- Waveforms: Airway pressure-time, flow-time, volume-time, ...
- Trends (8 anyone configurable): FiO2, MV, VT, f, PEEPi, R, C, etCO2, ...
- Loops: Paw-V, V-Flow, Flow-Paw, ...
- Capnography (etCO2) (optional): 0 to 100 mmHg
- CO2 production (VCO2): 0 to 999 mL/min, STPD*
- Serial dead space Vds: 0 to 999 mL, BTPS*
- Dead space ventilation (Vds/VT): 0 to 99 %
- O2 saturation: SpO2, pulse
Alarms / Monitoring
- Airway pressure: High / Low
- Expired minute volume: High / Low
- Tidal volume: High
- Apnea alarm time: 5 to 60 s
- Spontaneous breath frequency: High
- Inspired O2 concentration: High / Low
- Breathing gas temperature: High
- SpO2 pulse (optional): High / Low
- etCO2 (optional): High / Low
Performance data
Leakage compensation
Hose system compensation
Outlet for pneumatic nebulizer
Operating data
- Mains power connection: 110 to 240 V, 50/60 Hz, 10 to 30 V DC (optional)
- Power consumption: Approx. 125 W
- Gas supply operating pressure: O2, air: 2.7 to 6 bar / 39 to 87 PSI
Physical Specifications
- Dimensions ventilator (without trolley): 530W x 290H x 450D cm (20.9 x 11.4 x 17.7 inches)
- Weight basic unit Approx. 29 kg (64 lbs.)
Machine outputs
- Digital output: Output and reception via an RS 232 C interface
- Digital output: Output for independant lung ventilation (ILV)
- Digital output: (optional) For output and reception via two RS 232 C interfaces
- Analog output (optional): For analog output of two measured values