Philips HeartStart XL Desfibrilador
Condición REFURBISEHD
Product Specifications
Physical
Defibrillator Model | HeartStart XL (M4735A ) |
Dimensions |
19.0 cm (H) x 37.6 cm (W) x 34.6 cm (L) (7.5 in. x 14.8 in. x 13.7 in.)
|
Weight |
Weight: 6.0 kg (13.3 lbs.) including battery and full roll of paper. |
Environmental and physical requirements
Temperature |
0º C to 55ºC operating; -20º to 70ºC storage. Charging the battery at temperatures above 35ºC may degrade battery life. Storing the battery for extended periods at temperatures above 40ºC will reduce battery capacity and degrade battery life.
|
Humidity |
Up to 95% Relative Humidity
|
Altitude |
Operating: up to 15,000 ft. Storage: up to 15,000 ft.
|
Shock |
Philips Medical Systems, Section 760 Class B1 Drop Test (200 G’s <3 msec pulse). |
Vibration |
Philips Medical Systems, Section 759 Class B1 Vibration.
|
Water Resistance |
Meets IEC 60601-2-4, IPX 0.
|
EMC |
Meets EN 60601-1-2 |
Safety |
Meets IEC 60601-1 (EN 60601-1), UL 2601-1, CAN/CSA C22.2 No. 601-1.
|
Mode of Operation |
Continuous. |
AC Line Powered |
100-240 VAC, 50/60 Hz, 1.5A (Class 1) |
Battery Powered |
12 V rechargeable, SLA |
Display
Type |
LCD - TFT Color Liquid Crystal Display
|
Size |
111.4 mm x 83.5 mm. |
Resolution |
320 x 240 pixels |
Sweep Speed |
29 mm/s nominal (stationary trace; sweeping erase bar). |
Viewing Time |
4 seconds |
Battery
Type |
2 Ah, 12V, rechargeable, Sealed Lead Acid
|
Dimensions |
2.4 in. (H) x 0.94 in. (W) x 7.2 in. (D) (61.7 mm x 23.9 mm x 182 mm).
|
Weight |
1.4 lbs. (0.65 kg)
|
Charge Time |
Approximately 14.5 hours to 100%. Approximately 3 hours to 90%, indicated by LED on front panel. |
Capacity |
100 minutes ECG monitoring or 50 full-energy discharges or 75 minutes ECG monitoring while pacing (with a new, fully charged battery at room temperature, 25º C). |
Battery Indicators |
LOW BATTERY message appears on display when at least 10 minutes of monitoring time and 5 maximum energy discharges remain (with a new battery at room temperature, 25º C). |
Battery Storage |
Should not be stored above 40ºC for extended periods of time. |
Charger Output |
Unit can be operated using only AC Power, with no battery installed. |
Defibrillator
Waveform
|
Waveform: Biphasic Truncated Exponential. Waveform parameters adjusted as a function of patient impedance.
|
Shock Delivery |
Via multifunction defib electrode pads or paddles. |
Charge Time
|
Less than 3 seconds to 200 Joules with a new, fully charged M3516A SLA battery pack at 25ºC. Less than 15 seconds to 200 Joules when powered by AC with no battery installed.
|
Patient Impedance Range
|
Minimum: 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation)
Maximum: 180 Ohm |
SpO2 pulse oximetry
Wavelength Range |
500 to 1000 nm.
|
Resolution |
1%
|
ECG Monitoring
Inputs |
Single channel ECG may be viewed on display and printed. Pads ECG is obtained through 2 multifunction defibrillation electrode pads. Lead I, II, or III is obtained through the 3-lead ECG cable and separate monitoring electrodes. With a 5-lead cable, lead aVR, aVL, aVF, and any one of the V (1-6) leads can also be obtained.
|
Lead Fault |
LEADS OFF message and dashed line appear on the display if an electrode or lead wire becomes disconnected.
|
Paddle Fault |
NO PADDLES CONNECTED message and dashed line appear on the display if paddles become disconnected.
|
Pad Fault |
PADS OFF message and dashed line appear on the display if the pads become disconnected. |
Heart Rate Display |
Digital readout on display from 15 to 300 bpm, with an accuracy of ±10%. |
Heart Rate Alarms |
Configurable pairs of low and high heart rate alarm limits: 30 to 100, 60 to 140, 90 to 160 and 120 to 200 bpm. |
ECG Size |
2.5, 5, 10, 20, 40 mm/mV |