This store requires javascript to be enabled for some features to work correctly.
GE AMX IV PORTABLE X-RAY
Condition REFURBISEHD
DESCRIPTION
Features
- MX-75 275k HU X-ray tube with a .75mm focal spot
- GE AMX-IV collimator
- High-quality image
- Forward and reverse variable speed
- Completely mobile
- LED display
- Operates at full power with no power connection
- 24 kVp stations
- 30 mAs stations
- 100 mA constant
- kVp 50 - 125
- mAs 0.4 - 320
SPECIFICATIONS
Physical Weight & Dimensions
- Height: 76 inches (1,930 mm)
- Width: 25-3/16 inches (640 mm)
- Depth: 45-3/8 inches (1,153 mm)
- Weight: 1,050 lbs (477 kg)
Battery
Nine 12.9 volt batteries connected in series provide approximately 116 volt at full charge. Battery capacity is approximately 20,000 mAs at 100 kVp when fully charged and under specific conditions. Actual mAs capacity depends on the condition of the batteries, use of collimator lamp, electric brakes, rotor, and distance driven.
Movements
(tube vertical movement measured at the focal spot)
- Range: At least 52.5" (1,334 mm)
- Lowest position: 26.1" (663 mm) maximum from floor
- Highest position: 78.6" (1,996 mm) minimum from floor
- Horizontal movement measured at focal spot relative to column face: 24" (610 mm) minimum to 40" (1,016 mm) maximum
- Tube column rotation measured from horizontal latch: 360°
- Tube and yoke rotation around horizontal arm measured from tube port down position: Range (360°), detent locations (0, ±90°, ±180°)
- Tube trunion rotation measured from tube port down position: Range (120°), forward (110°), backward (10°), detent (0°, 90°)
- Collimator rotation measured from the front of the collimator with the tube port facing down: Range (180°), right (90°), left (90°), detent (0°, 90°)
Drive Speeds
- Speed 1: Drive speed with horizontal arm secured for support - 264' (6,705 mm) per minute ±25%
- Speed 2: Maneuvering speed with horizontal tube arm removed from the transport latch - (30% to 60% of drive speed)
Drive speed is measured on a smooth, hard and level surface. Speed will be reduced by inclines, carpeted or soft surfaces.
Reproducibility
Coefficient of variation of radiation output is less than 0.045 for successive exposures having constant technique factors.
Collimator
Minimum source to skin distance is limited to more than 30 cm by the skin spacers at the beam exit of the collimator. Full 17" × 17" (43 cm x 43 cm) radiographic coverage at 40" (1.02 mm) source to image distance. Minimum inherent filtration of 2.0 mm aluminum equivalent at 100 kVp.
Light Filed Intensity
The average illumination at a distance of 100 cm (39.37") from the focal spot shall be 16 foot candles (170 lux) or more.